รู้จักสินค้านี้
โมดูลแปลงไฟ 220v เป็น 5v 2A Hi-link HLK-10M12 Power supply 220v to 5V AC-DC ultra-small isolated
AC-DC 220V to 5V 2A isolating switch power supply module/ step-down module
1. Product features:
- Meet UL, CE requirements,
- Ultra-thin, ultra-small
- All voltage input (AC: 90 ~ 264V)
- Low ripple and low noise
- Output overload and short circuit protection
- High efficiency, high power density
- The product is designed to meet the requirements of EMC and Safety Test
- Low power consumption, environmental protection, no-load loss 0.1W
- 100% load aging and tested.
2. Environment Condition
Item Name
Technical Criteria
Unit
Operation Temperature
-20+60
Centigrade
Store Temperature
-40+80
Centigrade
Relative humidity
595
%
Cooling way
Cooling by radiation
Atmospheric pressure
80106
Kpa
Sea level elevation
2000
m
Vibration
Vibration coefficient 10~500Hz,2G10min./1cycle, 60min.each along X,Y,Z axes
3.Electrical Characteristic
1. Input characteristics (test at room temperature 20 C).
Item Name
Technical Criteria
Unit
Rated input voltage
100-240
VAc
Input voltage range
90-264
VAc
Maximum input current
0.2
A
Input current surge
10
A
maximum input voltage
270
VAc
Enter slow start
50
mS
Input Low Voltage Efficiency
Vin=110VAc,Output full-load69
%
Input High Voltage Efficiency
Vin=220VAc,output full-load70
%
Long-term reliability
MTBF100,000
h
Load rated output voltage
+50.1
VDc
Full rated output voltage
+50.2
VDc
Short-term maximum output current
1200
mA
The maximum output current for a long time
1000
mA
Voltage Regulation
0.2
%
Load Regulation
0.5
%
Output ripple and noise
(mVp-p)
70
Rated input voltage, full load. Using 20MHz of bandwidth,
The load side 10uF and 0.1uF capacitor to be tested.
mV
Switch overshoot amplitude
(Rated input voltage and output load plus 10%)5
%VO
Output over-current protection
150-200% of the output maximum load
A
Output short circuit protection
Direct short circuit at the normal output, automatically resume normal operation after a short circuit removal
2. Output characteristics (test at room temperature 20 C).
Project Name
Technical Criteria
Unit
Note
No-load rated
output voltage
50.1
Vdc
Full load rated
output voltage
50.2
Vdc
Short-time
maximum output
current
2200
mA
Long time maximum
output current
2000
mA
voltage regulation
0.2
%
load regulation
0.5
%
Output ripple and
noise
(mVp-p)
50
Rated input voltage, full output load. Using
20MHz bandwidth oscilloscope,
Load side and 10uF and 0.1uF capacitors are
tested.
mV
Switching machine
overshoot
amplitude
(rated input voltage, output plus 10% load)5
%V o
Output over-current
protection
110-150% of maximum output load
A
Output short circuit
protection
Direct short circuit in normal output and
automatic return to normal operation after
removal of short circuit
No damage to the whole
machine
4.Safety Characteristics:
4.1 Products designed to meet UL, CE safety certification requirements.
4.2 Safety and electromagnetic compatibility
Designed with the input of 2A UL certified insurance;
PCB board using double-sided copper clad plate production, material for the 94-V0 fire rating level;
Safety standards: Compliance with UL1012, EN60950, UL60950
Insulation voltage: I / P-O / P: 2500VAC
Insulation resistance :I / PO / P 100M Ohms / 500VDC 25 C 70% RH
Conduction and radiation :comply with EN55011, EN55022 (CISPR22)
Electrostatic discharge :IEC / EN 61000-4-2 level 4 8kV / 15kV
RF radiation Immunity: IEC / EN 61000-4-3 See Application Note
4.3 Temperature safety design
At room temperature, the capacitors of this power , the inner surface of the main converter maximum temperature does not exceed 90 C;
Shell maximum surface temperature does not exceed 60 C